Part Number Hot Search : 
105K250A 3C101 0M106 BCR08AM P1011 LVCH16 APTGT20 YMF753
Product Description
Full Text Search
 

To Download DMA21248S12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 DC-DC
212 Watts DMA Series
* * * * * * *
xppower.com
Open Frame Telecom DC-DC Converter -48 VDC Input ETSI Compliant NEBS Compliant 5 V Standby & 12 V Fan Outputs Remote On/Off & Power Good Signal AC Input Version Available (EMA212)
Specification
Input
Input Voltage Range Input Current Input Reverse Voltage Protection Input Transient Undervoltage Lockout Protection Fusing * 48 VDC nominal (36 - 75 VDC). Can be configured as -48 VDC input * 5 A typical. 7 A max. * Continuous protection with automatic recovery * Compliant with ETSI EN300 132:2003 * 32 - 35V DC * 15 A F rated in -ve line
General
Efficiency Isolation Voltage * 88% typical * 1500 VDC Input to Output (basic insulation), 1000 VDC Input to Ground, 500 VDC Output to Ground. * 60 kHz typical * 11 W/In3 * Combined input & DC OK - Open collector referenced to output 0 V, transistor normally off when input & output good. Input fail provides 5 ms warning of loss of output from input failure. DC OK provides warning of DC output failure. * 550 kHrs per MIL-HDBK-217F
Switching Frequency Power Density Signals
Output
* V1: 12 V, see table * Not fitted * 10% minimum load required on V1 to meet all specification parameters of V2 & V3. Line Regulation * V1:0.5%, V2: 5%, V3:3% of nominal with input variation of 36-75 VDC Load Regulation * V1:1%, V2: 5%, V3:3% of nominal with load variation 10-100% Setpoint Accuracy * V1:1%, V2: 5%, V3:3% of nominal with 48V DC input and 50% load Turn-on Time * 2 s typical from application of DC input Transient Response * <4% deviation with a 50-75-50% load change at 1 A/s. Output returns to within 1% in less than 500 s Ripple & Noise * 1% max pk-pk 20MHz bandwidth Overvoltage Protection * V1:115-140% of nominal, recycle input DC to reset Overload Protection * V1:110-125% of max current Short Circuit Protection * Continuous protection, trip and restart (hiccup mode) characteristic Temperature * 0.02%/C (after 20 minute warm up) Coefficient Output Voltage Output Voltage Trim Minimum Load MTBF
Environmental
Operating Temperature * 0 C to +50 C with full load, derate linearly to 50% load at 70 C with force cooling 10CFM minimum Cooling * Forced cooled (see operating temperature) Operating Humidity * 0 to 95% RH non condensing. (1,3) Storage Temperature * -40 C to +80 C. (2,3) Storage Humidity * 0 to 95% RH non condensing.(2,3) Operating Altitude * 3000m.(3) Shock * 3 shocks in each axis (total 18 shocks) 30g 11ms (half sine). (1,4) Vibration * 2g, 10 - 500Hz 10 sweeps. (1,5)
EMC & Safety
Emissions * EN61204-3 2000, EN55022 class A conducted & radiated, ETSI EN 300 132-2 2003, ETSI 300 386-1 1994, NEBS GR1089-CORE issue 4 * EN61000-4-4 level 1 Perf Criteria A, ETSI 300 386-1 1994 * EN61000-4-5 level 1 Perf Criteria A, * EN61000-4-6 level 2 Perf Criteria A, ETSI 300 386-1 1994, NEBS GR-1089-Core issue 4 * ETSI EN 300 132-2 2003 * EN60950-1:2006, CSA-C22.2 No. 609501-03, CB Report IEC60950-1:2005, CE Marked to LVD
EFT/Burst Surge Conducted Immunity
Notes
1. Compliant with ETS 300 019-1-3 May 1992 + ammendment 1 June 1997 class 3.1. 2. Compliant with ETS 300 019-1-1 Feb 1992 class 1.1, ETS 300 019-1-2 Feb 1992 class 2.2. 3. Compliant with NEBS GR-63-Core issue 3. 4. Compliant with EN60068-2-27. 5. Compliant with EN60068-2-6.
Narrow & Wide Band Noise Safety Approvals
DC-DC
Models and Ratings
Max Output Power (10 CFM Air Flow) 212 W Output Voltage V1 12.0 VDC Output Current (10 CFM Airflow) 16.7 A Fan Output V2 12.0 V/1.0 A Standby Supply V3 5.0 V/0.1 A
DMA
Model Number DMA21248S12
Mechanical Details
5.00 (127.0) 0.22 (5.7) 4.55 (115.6)
4 X o 0.14 (3.5) MOUNTING HOLES
0.22 (5.7)
CN2
CN2
AIR FLOW 12 CFM
2.55 (64.8)
CN1 (SCREW TYPE)
CN3 (SCREW TYPE)
1.14 (28.9)
0.62 (15.8)
0.23 (5.7)
SAFETY EARTH - 4.8 mm Faston
0.23 (5.7)
1.28 (32.6)
0.06 (1.6)
0.08 (2.0)
PIN CONNECTIONS - CN1 1 2 0.25" Faston -Vin +Vin Earth
PIN CONNECTIONS - CN2 1 2 3 4 5 6 7 8 9 10 +V2 V2 Return V2 Return ROF ROF Return Input Fail/DC OK Current Share +V3 -V3 +V2
PIN CONNECTIONS - CN3 1 2 +V1 V1 Return
Mating Connectors: CN2: Molex housing 511101050 and crimp 503948100.
Notes
1. 2. 3. 4. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) Units supplied with screw terminal (CN2) as standard. For faston type, add suffix `-F' to the part number. All 4 mounting positions should be connected to safety earth. The air flow needs to be directed through the power supply within the end application.
01-Aug-08


▲Up To Search▲   

 
Price & Availability of DMA21248S12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X